Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Protein & Cell ; (12): 48-58, 2010.
Article in English | WPRIM | ID: wpr-757707

ABSTRACT

Rabbit hemorrhagic disease was described in China in 1984 and can cause hemorrhagic necrosis of the liver within two or three days after infection. The etiological agent, rabbit hemorrhagic disease virus (RHDV), belongs to the Lagovirus genus in the Caliciviridae family. Compared to other calicivirus, such as rNV and SMSV, the structure of Lagovirus members is not well characterized. In this report, structures of two types of wild RHDV particles, the intact virion and the core-like particle (CLP), were reconstructed by cryo-electron microscopy at 11 &0A and 17 &0A, respectively. This is the first time the 3D structure of wild caliciviruses CLP has been provided, and the 3D structure of intact RHDV virion is the highest resolution structure in Lagovirus. Comparison of the intact virion and CLP structures clearly indicated that CLP was produced from the intact virion with the protrusion dissociated. In contrast with the crystal structures of recombinant Norovirus and San Miguel sea lion virus, the capsomers of RHDV virion exhibited unique structural features and assembly modes. Both P1 and P2 subdomains have interactions inside the AB capsomer, while only P2 subdomains have interaction inside CC capsomer. The pseudo atomic models of RHDV capsomers were constructed by homology modeling and density map fitting, and the rotation of RHDV VP60 P domain with respect to its S domain, compared with SMSV, was observed. Collectively, our cryo-electron microscopic studies of RHDV provide close insight into the structure of Lagovirus, which is important for functional analysis and better vaccine development in the future.


Subject(s)
Animals , Rabbits , Amino Acid Sequence , Caliciviridae Infections , Virology , China , Cryoelectron Microscopy , Hemorrhagic Disease Virus, Rabbit , Molecular Sequence Data , Sequence Alignment , Viral Structural Proteins , Chemistry , Virion
2.
Journal of Central South University(Medical Sciences) ; (12): 672-674, 2009.
Article in Chinese | WPRIM | ID: wpr-406278

ABSTRACT

Objective To discuss a new temporal bone tomography radiographic technique for the assessment of cochlear implantation and its clinic value. Methods Plane radiographs of both the temporal bone tomography and cochlear position tomography were taken on 10 children after cochlear implantation. The numbers of inserted electrodes of both techniques were compared. Results The inserted electrodes were shown clearly in both techniques. There was no difference in the data be-tween the 2 methods and between the operation and radiography outcomes (P>0.05). Conclusion Temporal bone tomography is a new method to evaluate cochlear implants in postoperative patients.

3.
Journal of Central South University(Medical Sciences) ; (12): 675-679, 2009.
Article in Chinese | WPRIM | ID: wpr-406277

ABSTRACT

Objective To explore the improvement effect of SLOT Scan technology (narrow seam exposure capture technology) and the radiography techniques on the quality of the scoliosis X-ray films in teenagers. Methods The Sonialvision Satire Ⅱ equipment of Shimadzu corporation and SLOT Scan were applied to take the radiography for 60 patients taller than 1.50 metres. All the data were collected through a continual exposure, and the images were sewn up through a seamless connec-tion software. Results Cervical, thoracic, and lumbar and sacral segments could clearly present at the same time on one X-ray film by seamless splicing, and the quality of one time radiograph was as good as one film. Conclusion As a new radiology technique, SLOT Scan can wipe off splitting arti-fact effectively and make the whole spine seamless present on one X-ray film. It helps the spinal sur-geons to observe, calculate and measure accurately. It is useful to choose the operation mode and judge the curative effect.

4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-587514

ABSTRACT

This paper introduces an ECG real time monitoring system based on LabVIEW.With Wavelet transformation,the original ECG signals are processed to increase the accuracy of R peak detection.The feature of real time in this system is ensured by the application of simplified algorithm.The result panel offers various types of HRV information in time domain,including numerical and graphical displays which make the data more intuitional and more convenient to obtain.The system runs well in lab and the result is acceptable.

SELECTION OF CITATIONS
SEARCH DETAIL